Illumination/viewing system |
Reflectance: |
di:8°, de:8° (diffuse illumination: 8° viewing)
SCI (specular component included)/SCE (specular component
excluded) switchable
Conforms to CIE No. 15, ISO 7724/1, ASTM E 1164, DIN 5033
Teil 7, and JIS Z 8722 (Condition c) |
|
Transmittance: |
di:0°, de:0° (diffuse illumination: 0° viewing) |
|
Integrating sphere size |
Ø152 mm |
|
Detector |
Dual 40-element silicon photodiode arrays |
|
Spectral separation device |
Planar diffraction grating |
|
Wavelength range |
360 nm to 740 nm |
|
Wavelength pitch |
10 nm |
|
Half bandwidth |
Approx. 10 nm |
|
Measurement range |
0 to 175 % (Reflectance or transmittance); Output/display
resolution: 0.01% |
|
Light source |
Pulsed xenon lamp |
|
Measurement time |
Approx. 1 s (to data display/output); Minimum measurement
interval: Approx. 3 s |
|
Measurement/illumination area |
Reflectance: |
Changeable by changing mask and settings. LAV: Ø30 mm/Ø36
mm; MAV (optional): Ø8 mm/Ø11 mm; SAV (optional): Ø3 mm/Ø6
mm |
|
Transmittance: |
Ø20 mm |
|
Repeatability |
Spectral reflectance: Standard deviation within 0.1% (400
nm to 740 nm)
Chromaticity value: Standard deviation within ΔE*ab 0.04
* When a white calibration plate is measured 30 times at
10-second intervals after white calibration |
|
Inter-instrument agreement |
Within ΔE*ab 0.15 (Typical) (LAV/SCI)
(Based on 12 BCRA Series II color tiles compared to values
measured with a master body under Konica Minolta standard
conditions) |
|
Transmittance chamber |
No sides (unlimited sample length); Depth (maximum sample
thickness): 60 mm
Sample holders (optional) for holding sheet samples or
containers of liquid samples can be installed/removed |
|
Display |
5.7-inch TFT color LCD |
|
Display languages |
English, Japanese, German, French, Italian, Spanish,
Simplified Chinese |
|
Operating temperature/humidity range |
13 to 33°C, relative humidity 80% or less with no
condensation |
|
White/100% calibration |
Automatic white (reflectance)/100% (transmittance)
calibration using internal white calibration plate
(Not applicable to 100% calibration when using cells for
transmittance measurements of liquids.) |
|
Interfaces |
USB 1.1 (Connection to PC; USB memory stick); RS-232C
standard (Connection to serial printer) |
|
Observer |
2° Standard Observer or 10° Standard Observer |
|
Illuminant |
A, C, D50, D65, F2, F6, F7, F8, F10, F11, F12, ID50, ID65
(simultaneous evaluation with two light sources possible) |
|
Displayed data |
Spectral values, spectral graph, colorimetric values,
color-difference values, color-difference graph, pass/fail
judgment, pseudo color, color assessment |
|
Color space |
L*a*b*, L*C*h, Hunter Lab, Yxy, XYZ, Munsell, and color
differences in these spaces (except for Munsell) |
|
Index |
Reflectance: |
MI; WI (ASTM E 313-73, ASTM E 313-96); YI (ASTM E 313-73,
ASTM E 313-96, ASTM D 1925);
ISO Brightness; B (ASTM E 313-73) |
|
Transmittance: |
Gardner; Iodine Color Number; Hazen/APHA; European
Pharmacopoeia; US Pharmacopeia |
|
User index |
User-defined index |
|
Color-difference equation |
ΔE*ab (CIE 1976), ΔE*94 (CIE 1994), ΔE00 (CIE 2000), ΔE
(Hunter), CMC (l: c) |
|
Pass/fail judgment |
Tolerances can be set to colorimetric values (except
Munsell), color-difference values, or reflectance index
values |
|
Storable data |
Measurement data: 4,000 measurements; Target color data:
1,000 measurements |
|
USB memory stick* storage |
Storage of measurement data and target color data.
Storage/reading of measurement condition settings
* Security-enabled USB memory sticks cannot be used. |
|
Power |
AC 100 to 240 V, 50/60 Hz (using exclusive AC adapter) |
|
Size |
Slide cover closed: 385 (W) × 192 (H) × 261 (D) mm
Slide cover open: 475 (W) × 192 (H) × 261 (D) mm |
|
Weight |
Approx. 5.8 kg |
|
Operating temperature/humidity range |
13 to 33°C, relative humidity 80 % or less (at 35°C) with
no condensation |
|
Storage temperature/ humidity range |
0 to 40°C, relative humidity 80 % or less (at 35°C) with
no condensation |
Specifications are subject to change without notice.